Download Datasheet 
Note: the Z-SG is the old model with outdated firmware and functions. We strongly recommend that you go for the new Z-SG2, which is much newer and has more features.
Z-SG is a strain gauge signal converter. Measurements taken using the 6-wires or 4-wires technique are available through Modbus-RTU serial protocol or the analog output. Sensitivity from 1 to 64mV/V, settable by DIP-switch for integer values, via software for real/integer values by connecting to the device via the microUSB port on the front panel. Stable weight indication via Modbus register/digital output. Remote writing of the tare in volatile and/or non-volatile memory by digital input/Modbus register/Modbus commands. Z-PC-DINAL2-17.5, Z-PC-DIN2-17.5, and Z-PC-DIN8-17.5 are mandatory accessories for ModBUS configurations.
Very easy to program via USB and FREE PC software or Android software
General characteristics
- ADC with 24bit resolution
- 4 wires or 6 wires load cell measure mode
- Compression / Tension (Bi_Drectional) or 1 direction mode
- 1 analog output configurable in Current or Voltage mode (only Z-SG model)
- Load cell sensitivity configurable from +-1mV/V to +-64mV/V or virtually every sensitivity
- Measure resolution configurable
- RS232 and RS485 port with Modbus RTU protocol
- Configurable Moving average filtering
- Digital input for Tare acquisition (only Z-SG model)
- General purpose Digital input or Digital output (only Z-SG-L model)
- Digital output with one configurable weight threshold or “stable measure” condition
- Modbus Station address and baud-rate configurable by Dip-Switches
- Multifunction instruments (converters, meters, stand alone/third-party integrated systems)
- 1 Analog input for reading (andpower supply) strain gauge load cells (6-wire isolated measurement)
- 1 Analog re-transmitted output of net weight in current (0..20, 4..20mA) or voltage (0..5, 0..10 V)
- 1 Digital Input/Output for operation settings
- Accuracy class 0,01%
- ModBUS RTU slave half duplex protocol
- Multiple calibration methods (with or without PC, known weight and load cell)
- Programmable functions via DIP switches or software: full scale, threshold exceeding, stable weighing
- Advanced functions (Z-SG2): configurable resolution, adjustable sampling rate from 5.4 Hz to 1365.3 Hz, adjustable threshold alarm, stabilized measurement by noise
- filter, “piece counter” function, automatic tare reset